I summarized the results of the PRCL/SRCL measurements performed so far.
-
When data were acquired at 160 MHz, 140 MHz, -140 MHz, and -160 MHz, and the uncertainties of the resonance frequencies were estimated visually:
klog:37184, klog:37185
PRX: 68.267(13) mklog:37191
PRY: 64.921(12) m
SRY: 64.941(13) m
SRX: 68.284(16) m
-
When data were acquired at 190 MHz, 160 MHz, 140 MHz, -140 MHz, -160 MHz, and -190 MHz, and the resonance frequencies were determined by fitting:
klog:37209
PRY: 64.9280(33) m
SRY: 64.9422(82) mklog:37223
PRX: 68.2688(46) m
SRX: 68.2818(45) mklog:37248
PRC: 66.5984(28) m
SRC: 66.6120(47) m
Schnupp asymmetry: 3.3405(48) m
-
When data were acquired at 1.6 GHz, 0.8 GHz, -0.8 GHz, and -1.6 GHz, and the resonance frequencies were determined by fitting:
klog:37250
SRY: 64.94397(50) mklog:37260
SRX: 68.2842(13) m
PRX: 68.26307(11) m
PRY: 64.92543(46) m
SRC: 66.61409(70) m
PRC: 66.59425(24) m
Schnupp asymmetry: 3.33791(45) m
-
After adjusting the height of the lens on the POS table, when data were acquired at 1.6 GHz, 0.8 GHz, -0.8 GHz, and -1.6 GHz, and the resonance frequencies were determined by fitting:
klog:37393
SRX: 68.2863(18) m
SRY: 64.95025(42) m
SRC: 66.61828(92) m
-
When data were acquired from the reflection signal of OMMT2 at 1.6 GHz, 0.8 GHz, -0.8 GHz, and -1.6 GHz, and the resonance frequencies were determined by fitting:
klog:37450
SRX: 68.28747(42) mklog:37455
SRY (HWP 14, polarizer 295): 64.94808(80) m
SRY (HWP 59, polarizer 250): 64.94959(71) m
SRC (SRY: HWP 14, polarizer 295): 66.61778(45) m
SRC (SRY: HWP 59, polarizer 250): 66.61853(41) mklog:37458
PRX: 68.26556(22) m
PRY: 64.92693(52) m
PRC: 66.59625(28) m
Schnupp asymmetry (SRY: HWP 14, polarizer 295): 3.33884(48) m
Schnupp asymmetry (SRY: HWP 59, polarizer 250): 3.33839(47) mklog:37466
SRY: 64.94972(93) m
SRC: 66.61860(51) m
Schnupp asymmetry: 3.33842(49) m
-
The results for PRX are summarized in Fig. 1, those for PRY in Fig. 2, those for SRX in Fig. 3, those for SRY in Fig. 4, those for PRC in Fig. 5, those for SRC in Fig. 6, and those for the Schnupp asymmetry in Fig. 7.