I implemented new calibration factor into MEDM.
After that, I requested ALIGNED state to guardian but faild due to some oscillation of OpLev controls.
So, I measured the TFs of PR2 and made susmpension models.
Figure 1 to 3 shows the measured TFs.
I haven't checked TML to TML but gains of TFs from TMP to TMP and TMY to TMY increase more than 10 dB.
So, I ajusted the gain of filters and now PR2 can reach LOCK_ACQUISITION state from the guardian now.
Note:
I'm not sure why TF gains to calibrated signals changes so much (of course, it is likely that old calibration is just wrong because PR2 TF gains are 10dB or more smaller than the other Type-B suspensions).
So, further investigation is necessary.
Yokozawa-san, I forgot to share the result. Sorry.
4. Characterization of power budget
Power budget is
IN : 0.918 mW
TILT : 0.130 mW
LEN : 0.204 mW