Modematching and modulation indices from X and Y arm cavity scan

[Kenta, Komori, M. Honjo, Michimura]

To estimate losses in the IFO, we did X arm and Y arm cavity scan to measure the modematching and modultion index.
Modematching is 97(1)% for Xarm and 94(1)% for Yarm for single arm case (numbers include misalignment).
Modulation index is 0.09(2) for f1 and 0.11(4) for f2, measured at arms, which is a factor of 2 smaller than the previous measurement in 2019.

What we did:
 - Locked Xarm and Yarm each with PRM misaligned.
 - Did a cavity scan using ALS, with the same method in klog #31112 and klog #30825 (scan was done by adding 27000 counts in K1:ALS-SUM_OFS_SLOWOUT_CALI_OFFSET and turning on/off FM1 that has -1 gain with a ramp time of 300 sec to do a linear scan)
 - During the cavity scan, LO frequency was 5.624 369 113 MHz.
 - GPS times of the scan are as follows.

startTime=1428131200  # Yarm scan April 8, 2025, misaligned, slow scan                                                                                               
durTime=350                                                                                                                                                            

startTime=1428130200  # Yarm scan April 8, 2025, aligned, slow scan                                                                                                     
durTime=350

startTime=1428139080  # Xarm scan April 8, 2025, misaligned, slow scan                                                                                                 
durTime=350                                                                                                                                                            

startTime=1428141500  # Xarm scan April 8, 2025, aligned, slow scan                                                                                                    
durTime=350


Result:
 - Attched are time series data during the scan, when the arms are aligned.
 - From (carrier TEM00 power)/(carrier TEM00 power + carrier TEM1 power + carrier TEM2 power), modematching was calculated.
 - Pure modematching calculated with (carrier TEM00 power + carrier TEM1 power)/(carrier TEM00 power + carrier TEM1 power + carrier TEM2 power) is 98.9(1)% for Xarm and 98.4(2)% for Yarm.
 - From 2*sqrt(upper or lower sideband TEM00 power / carrier TEM00 power), modulation index was calculated.
 - Uncertainties presented here is just a rough estimate.

Discussion:
  - As for modulation index, it was measured to be the following in 12 July 2019 (klog #9505), but it is somehow half now. What happened??
Modulation index of f1 @MIF = 0.22(2)
Modulation index of f2 @MIF = 0.23(2)

 - Resolving f1 from TEM1 was still very hard. They are too close (klog #30825).
 - It has been said that there is a 15% loss from BS to OMC DC PD during O4a from DARM shot noise. For this estimate, modematching between IMC output beam and PRFPMI was estimated using the modulation index of 0.2. We might want to re-evaluate using the updated modulation index.

Next:
 - Derive FSR, TMS (g-factor), Finesse from these measurements
 - Measure modematching between IMC output beam and PRFPMI using REFL power PRFPMI locked/unlocked (REFL PDA3 can be used, as this is not affected by HWP rotation during the lock)