CAL group
We did the calibration measurements.
Estimated parameters taken while visitors were present are as follows.
H_etmxtm = 3.850142293e-14 @10Hz ( 0.52% from previous measurements)
H_etmxim = 1.621508136e-14 @10Hz ( 3.2% from previous measurements)
Optical_gain = 2.126800024e12 ( 0.63% from previous measurements)
Cavity_pole = 18.183601559 Hz ( -0.16% from previous measurements)
Previous values are listed in klog#34310.
Fig. 2 and Fig.4 shows the ratio of the sensing functions estimated.
Post-tour measurement results (inside the mine) are as follows.
H_etmxtm = -3.830386471e-14 @10Hz ( -0.51% from above measurements)
H_etmxim = -1.565605347e-14 @10Hz ( -3.44% from above measurements)
Optical_gain = 2.127919074e12 ( 0.05% from above measurements)
Cavity_pole = 18.267333924 Hz ( 0.46% from above measurements)