A CAL Tcam session was performed to obtain beam position information necessary for Pcal. The parameters have already been updated, and SDF is expected to be accepted.
Operator: Shingo Hido, Dan Chen
Update Time: 2025/06/27 15:07:49
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EX_TCAM_PATH1_X | 2.88640 mm | 3.26544 mm | +0.37904 mm |
| K1:CAL-PCAL_EX_TCAM_PATH1_Y | 62.47329 mm | 62.90884 mm | +0.43555 mm |
| K1:CAL-PCAL_EX_TCAM_PATH2_X | -0.61257 mm | 0.13975 mm | +0.75232 mm |
| K1:CAL-PCAL_EX_TCAM_PATH2_Y | -64.03091 mm | -63.65513 mm | +0.37578 mm |
Update Time: 2025/06/27 15:08:24
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EX_TCAM_MAIN_X | 3.03211 mm | 3.47421 mm | +0.44210 mm |
| K1:CAL-PCAL_EX_TCAM_MAIN_Y | 13.17965 mm | 12.21899 mm | -0.96066 mm |
Update Time: 2025/06/27 15:09:03
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EY_TCAM_PATH1_X | 1.21765 mm | 0.79868 mm | -0.41897 mm |
| K1:CAL-PCAL_EY_TCAM_PATH1_Y | 64.54810 mm | 64.20560 mm | -0.34250 mm |
| K1:CAL-PCAL_EY_TCAM_PATH2_X | -0.42913 mm | -0.69337 mm | -0.26424 mm |
| K1:CAL-PCAL_EY_TCAM_PATH2_Y | -69.98229 mm | -70.20718 mm | -0.22489 mm |
Update Time: 2025/06/27 15:09:35
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EY_TCAM_MAIN_X | 8.25404 mm | 6.50798 mm | -1.74606 mm |
| K1:CAL-PCAL_EY_TCAM_MAIN_Y | -3.31986 mm | -3.22455 mm | +0.09531 mm |