Reports 1-1 of 1 Clear search Modify search
CAL (General)
Shingo Fujii - 18:17 Wednesday 27 September 2023 (26932) Print this report
Preparations for modifications in PCAL MODELS
Fujii,  YamaT

We prepared for PCAL MODEL modifications.
Specifically. we replaced cdsEpicsIn with cdsFilt in the following channels of the Pcal model to adjust GAIN and OFFSET on filter bank.

Channels:
1_OFS_OFFST_V_SET
1_OFS_GAIN_V_SET
2_OFS_OFFST_V_SET
2_OFS_GAIN_V_SET

It is still in progress, so please contact me or YamaT-san if you want to "make" models.
Comments to this report:
Shingo Fujii - 17:06 Friday 10 November 2023 (27588) Print this report

We were to unable to prepare pcal guardian for model update at Friday work.
So, the model was restored to its original version and added new text monitor channnels, CAL-PCAL_EX_CURRENT_TIME, CAL-PCAL_EY_CURRENT_TIME.
After guardian modifications for the new model are completed, pcal models will be changed to one same as model update.