Reports 1-1 of 1 Clear search Modify search
VIS (PR2)
ryutaro.takahashi - 15:00 Wednesday 22 June 2022 (21231) Print this report
Health check of PR2

I checked DC responses from each actuator to each sensor. The coefficients of H2 and H3 in IM should be larger than H1. Please compare with PRM and PR3.

BF damper (LVDT)

  [um/count]
V1 0.0033
V2 0.0026
V3 0.0023
H1 0.029
H2 0.032
H3 0.030

IM (OSEM)

  [um/count]
V1 0.008
V2 0.009
V3 0.009
H1 0.017
H2 0.014
H3 0.017