Reports 1-1 of 1 Clear search Modify search
VIS (EY)
dan.chen - 6:50 Friday 15 May 2026 (36900) Print this report
ETMY tripped during initial alignment

Summary

As reported in klog 36899, I tried to perform the initial alignment.
During the procedure, ETMY went into the tripped state.
I checked the related signals and found that the GAS F3 signal had been gradually increasing since yesterday. This issue needs further investigation and treatment.

Details

During the initial alignment procedure, I requested IRY_LOCKED in the initial alignment GRD. Then, ETMY was tripped.

The trip seemed to be triggered by a large signal K1:VIS-ETMY_F2_WD_AC_BANDLIM_GAS_OUT16. (fig_001)

I cleared the suspension trip and checked the GAS signals. I found that the F3 signal had started to increase suddenly last night, although this signal had already been relatively large before. (fig_002)
Also, it seems that the GASs were oscillating in the LOCK_ACQUISITION state. (fig_003)

(The suspension can be state at the MISALIGNED state, which had been kept overnight.)

Images attached to this report
Comments to this report:
dan.chen - 7:09 Friday 15 May 2026 (36901) Print this report

It seems not only F3, but other GAS filer outputs were also goning up from the beginning of May.

Images attached to this comment
dan.chen - 9:58 Friday 15 May 2026 (36902) Print this report

The GAS output changes with temperature graphs for all Type A suspentions.

We can see a large temperature change from 3rd May, and a small changes from 2 days ago.

Offloads seem to be needed.

Images attached to this comment