with Dan, YamaT, SawadaT
We performed full measurements for the IFO calibration.
The analysis results will be posted at a later date.
Notes:
The DARM-related measurements were conducted after adjusting the feedforward gains (see klog#34410).
Following the same method as klog#34040 and klog#34033, we performed measurements to observe the changes in DC caused by differences in the number of whitening filter stages for ITMX-TM and BS-TM.
Measurement files (`/users/CAL/current/measurements/2025/0603/0920_*`):
0920_BS_TM_PRCL.xml : Whitening = 1 stage
0920_BS_TM_PRCL-1.xml : Whitening = 0 stage
0920_ITMX_TM_DARM_PRFPMI_WFOFF.xml : Whitening = 0 stage
0920_ITMX_TM_DARM_PRFPMI_WFON.xml : Whitening = 3 stages