Reports 1-1 of 1 Clear search Modify search
ISC (General)
satoru.takano - 8:43 Friday 13 November 2026 (37838) Print this report
Comment to Investigation of Missing MICH Signal in DRMI 3f Control (37835)

I ran a finesse script and confirmed that REFL135 (and POP45) is much more sensitive to the BS motion than REFL51 (and POP17). Probably better decoupling of the BS motion or actuating MICH in different ways (eg. both ITMs oppositely) is necessary. You'll see the finesse code here.

Fig. 1 shows the frequency response of the sensors (1f/3f, f1/f2, POP/REFL) when we move BS for MICH control; blue-orange lines are for 1f, green-red lines are for 3f. The demodulation phases of POP45 and REFL135 are optimised for PRCL, and those of POP17 and REFL51 are optimised for SRCL. The most sensitive signal to BS motion is REFL135I, and it's ~ 400 times more sensitive than REFL51Q.

Fig. 2 shows the frequency response when we move the ITMs in the opposite direction, rather than BS, to keep PRCL and SRCL unchanged. In this case, the signals are well decoupled, of course.

I'm not sure how precisely the actuators are decoupled in terms of DoFs for DRMI, but much harder decoupling would be necessary to resolve the coupling between REFL51-REFL135 and PRCL-MICH.

Images attached to this comment
Search Help
×

Warning

×