Reports 1-1 of 1 Clear search Modify search
VIS (SRM)
ryutaro.takahashi - 12:35 Sunday 08 November 2026 (37817) Print this report
Comment to Implementation of IP control with FLDACCs (36757)

I measured the IP tilt, which depends on the IP position. The IP position was changed with the setpoint for the LVDT L. The IP tilt was measured using the DC feedback signal in the FLDACC H1 (aligned to L). The plot shows that the DC acceleration in the FLDACC is proportional to the IP position. The coefficient was 2.8μg/mm which corresponds to 2.8μrad/mm in tilt.

Images attached to this comment