DetChar (General)takaaki.yokozawa - 9:28 Friday 05 June 2026 (37032)
Print this reportLock loss study during the O4c (up to middle August. 2025)[Tanaka, Ide, Hamayasu, Yanagi (Aogaku), Yokozawa]
We tried to perform to make the summary of the lock loss study during the O4c run, up to the middle of Aug. 2025. Total number of lock loss was 215, we checked them and we succeeded to apply tags to all lock loss during O4c August.
From the previous studies, we focused to distinguish following groups.
0. Request When the locked loss happened by the "request" (ex. maintenance, calibration, commissioning, trouble ) we checked this group. We didn't care which control became unstable in case of this group, of course.
1. Earthquake If the lock loss guardian tagged [EQ], we treat the lock loss caused by the large (including the low frequency ground motion) earthquake. We didn't care which control became unstable in case of this group.
2. 1 Hz ground motion It turned out the "nearby" earthquake which have the ground motion above 1 Hz. We checked the BLRMS IXV Z 1HZ3 and 3HZ10, and if there are relatively larger ground motion in 10s, we defined the 1 Hz lock loss. (Threshold is about 0.1 in 1HZ3 BLRMS) We didn't care which control became unstable in case of this group.
3. ETMY MN oplev glitch As you know, the sudden jump detected in ETMY MN TILT oplev, we saw several glitches in ETMY suspension. Some locked loss occurred by this glitch, by checking the control signals of ETMY suspensions, we tagged to this group.
4. IR trans and POP 90 I drop before the lock loss (tagged alignment) By checking the IR trans power and POP 90 I power, we tagged to this group. After the Yokozawa's investigation, the most case caused by the large motion of the 0.08 Hz in Type-A suspension. As you know, there are 0.08 Hz resonant frequency in Type-A suspension, if this motion excess the control range of the ASC, we loose the good alignment, IR trans and POP 90 I became lower and finally lock loss happened. We can see 0.08 Hz oscillation in ASC error signals in case this locked loss happened.
5. Quick saturation OMC DCPD (tagged quick) We defined the OMC DCPD suddenly saturated (order of a few miliseconds), we tagged to this group. After the Yokozawa's investigation, we may distinguish two groups; - Excitation of the violin mode As shown in Fig.1. , the similar glitch happened 2 sec before, the resonant frequency was about 180 Hz. So I guess some of quick saturation may be caused by the excitation of the violin mode resonant frequency. ID 16, 34, 37, 112, 115, 144, 147 would be the candidate of the this group - Unknown behavior This is quite interesting behavior that when quick saturation happened(Fig.2.), - the value of the OMMT2 TRANS DC decreased (60 -> 40 cnt) - the value of the AS PDA1 DC decreased (0.17 -> 0.09 ) - the value of the AS PDA1 RF17 Q ERR decreased (0.014 -> -0.001) AS0CROSS??? - the value of the REFL PDA1 DC increased (4 -> 14) I discussed with Ushiba-san, Tanaka-san, Takano-san and Fujimoto-san, but we cannot conclude it. If you notice something, please contact to me. ID 38, 114, 118, 185, 204 would be the candidate.
6. Slowly saturation OMC DCPD (tagged slow) If the behavior of the 0. - 5. didn't detect and we can see the several oscillation detected in OMC DC PD and saturation detected here, we tagged to this group. They would be come from the excitation of the resonant frequency of the cryo-payload (see detail in Ishikawa-san's master thesis JGWDoc17063)
Fig.3. showed the percentage of the lock loss during O4c up to the August. Fig.4. showed the resonant frequency for the slowly saturation OMC DCPD, by our eye and ndscope cousors We also generated several summary plots, they will appear soon.
We didn't care much for the EQ and 1Hz ground motion. This would be the next step.
Finally, I uploaded the txt file for lock loss tag.
Thank you very much for great work, Yuzurihara-san and many Aogaku members!
takaaki.yokozawa - 16:50 Wednesday 17 June 2026 (37085)
Print this reportVery preliminary investigation.
I plotted the BLRMSs (EXV Z) for all locked loss during O4c. I need more investigation, but just showed the plots. JGWDoc17395
takaaki.yokozawa - 8:08 Thursday 18 June 2026 (37087)
Print this reportI checked all locked loss events up to id=100.
- Tag : Slow, relatively larger ground motion 30 - 100 mHz Originally, we tagged the slow (20 - 60 Hz oscillation in OMC DCPD and saturation), but there seemed earthquake in 30 - 100 mHz region. We will check the ground motion and oscillation frequency, other signals more detail. ID = 11, 13, 32, 44, 45, 46, 47
- Tag : Quick, relatively larger ground motion high frequency > 1 Hz One event tagged quick lock loss (AS power decreasing, REFL power increasing), typical 1 Hz ground motion ID = 38
- Tag :1Hz, unknown ground motion Tagged 1 Hz, but not seemed earthquake, but long large ground motion > 1 Hz, we will check more detail using ndscope. ID = 59
- Tag : alignment, relatively larger ground motion 30 - 100 mHz In several locked loss tagged in alignment, we also detected relatively larger ground motion in low frequency. ID = 53, 60, 81,94 One lock loss tagged alignment, we cannot see large ground motion, I will check later ID = 99
- Tag : slow , but long large ground motion > 1 Hz It would be 1 Hz ground motion ID = 76
- Tag : 1 Hz, but no large ground motion It tagged 1 Hz, but no large ground motion, maybe typo, we need to check more ID = 82
Images attached to this comment
takaaki.yokozawa - 10:29 Thursday 18 June 2026 (37089)
Print this reportI checked all locked loss events from 101 to id=215.
- Tag : Slow, relatively larger ground motion 30 - 100 mHz Originally, we tagged the slow (20 - 60 Hz oscillation in OMC DCPD and saturation), but there seemed earthquake in 30 - 100 mHz region. We will check the ground motion and oscillation frequency, other signals more detail. ID = 159, 165
- Tag : Quick, relatively larger ground motion high frequency > 1 Hz ID = 114, 115, 185 (114,185 power change, 115 violin)
- Tag :1Hz, unknown ground motion Tagged 1 Hz, but not seemed earthquake, but long large ground motion > 1 Hz, we will check more detail using ndscope. ID = 111
- Tag : alignment, relatively larger ground motion 30 - 100 mHz In several locked loss tagged in alignment, we also detected relatively larger ground motion in low frequency. ID = 102, 105, 107, 120, 130, 166, 168, 172
- Tag : ETMY, 1 Hz ground motion Check ETMY signals and difference between other ETMY signals ID = 174
Images attached to this comment
takaaki.yokozawa - 12:20 Thursday 18 June 2026 (37091)
Print this reportMore plots (added the BLRMS), and histogram (orange tagged [EQ] or [1Hz], blue not tagged), 30MHZ100 and 1HZ3 would be significant.