hirotaka.yuzurihara - 14:45 Monday 28 July 2025 (34688) Print this report
lockloss investigation during O4c (2025/07/16~07/22)

[Shuta Tanaka, Ide, Obayashi (Aogaku), Yuzurihara]
We performed the lockloss investigation for the lockloss which happened between 2025/07/16~07/22. The previous lockloss investigation was posted in klog34687. During this period, there were 27 lockloss from the OBSERVATION state. The plots are listed in DAC wiki.

      Quick saturation of OMC DCPD

      For 1 lockloss (i=147), the quick saturation of OMC DCPD happened. This phenomena looks similar with the lockloss reported in klog34527. Compared with the usual saturation of OMC DCPD, the quickness (or the time scale) of the saturation is different. One of them have the ISC_WC_L label.
      Although we checked the other channels, we didn't find the coincidence change. If you find the coincidence with other channel, that's helpful to understand the cause behind the lockloss.

      Slowly saturation of OMC DCPD

      For 5 lockloss (i=133, 134, 138, 139, 140), the slowly saturation of OMC DCPD can be seen. The oscillation just before the saturation was 20~40 Hz. One of them have the ISC_WC_L label. The same phomena continued around this period.

      For 5 lockloss (i=144, 145, 146, 152, 153), the slowly saturation of OMC DCPD happened. The oscillation just before the saturation seems to be ~18 Hz. The same phomena continued around this period.

      Earthquake

      For 10 lockloss, the EQ label was asgned. During this period, many earthquakes occurred near the Tokara Islands even with small magnitude.

      Excess of 1~10Hz seismic motion

      For 4 lockloss (i=135, 141, 151, 158) (2 of them has also EQ label), 1Hz label was assigned. In addition, for 2 lockloss (i=150, 158), we found the excess of the 1Hz seismic motion.

      Alignment upward the AS port

      There was no lockloss related to the alignment upward the AS port.

      Lockloss by the human request

      For 2 lockloss, the REQ label was asigned.