Comment to Deployment of V2 IO-chassis and the front-end computer for EX0 (36654)

[YamaT, Nakagaki, Ikeda]

This work is related to K-Log#36654.

We used the new V2 IO chassis to measure the noise levels of the ADC and DAC.
For the DAC measurement, the Whitening Chassis used the S1402923 port (on the Board2 side).
Since the input side of this Whitening Chassis is a D-Sub 15-pin female connector, an adapter was required for connection.

During DAC measurements, the Whitening Chassis provided a 42 dB gain.

[Data]
/users/DGS/measurements/{ADC,DAC}/K1EX0/2026/0326_V2_IO_CHASSESS/
 