Model update to provide a better calibration of PMC

It's just a model preparation (a new model hasn't been deployed yet).

Characterization of PMC is in progress as reported in the thread of klog#35926. Because UGF of PMC loop is now not so higher than DGS band, calibrated PMC spectrum by using only PZT feedback on diaggui is not accurate especially above UGF. So a new PMC model was prepared to provide a better calibration of PMC by using both error and feedback signal as shown in Fig.1-3. All components are implemented in k1psl because CPU load of k1calcs is already almost full and also using new Dolphin connections is over-engineering.

This model will be deployed on maintenance day in near future.

Images attached to this report
Comments to this report:
takahiro.yamamoto - 12:28 Friday 26 December 2025 (35975) Print this report
A new model was deployed.
A calibrated signal will be available after checking sign of each component.

BTW, some SDF differences appeared as shown in Fig.1-2 when I restarted k1psl.
They seemed to be related numerical rounding issue. So I reverted them.
Images attached to this comment
Search Help
×