A CAL Tcam session was performed to obtain beam position information necessary for Pcal. The parameters have already been updated, and SDF has been accepted.
Operator: Dan Chen
Update Time: 2025/11/07 11:27:28
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EX_TCAM_PATH1_X | 0.33702 mm | 0.33957 mm | +0.00255 mm |
| K1:CAL-PCAL_EX_TCAM_PATH1_Y | 67.43505 mm | 67.14666 mm | -0.28839 mm |
| K1:CAL-PCAL_EX_TCAM_PATH2_X | -0.10011 mm | -0.19262 mm | -0.09251 mm |
| K1:CAL-PCAL_EX_TCAM_PATH2_Y | -63.12901 mm | -63.44511 mm | -0.31610 mm |
Update Time: 2025/11/07 11:28:31
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EX_TCAM_MAIN_X | 4.14543 mm | 4.10822 mm | -0.03721 mm |
| K1:CAL-PCAL_EX_TCAM_MAIN_Y | 12.29349 mm | 13.23050 mm | +0.93701 mm |
Update Time: 2025/11/07 11:29:07
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EY_TCAM_PATH1_X | 1.07761 mm | 1.08398 mm | +0.00637 mm |
| K1:CAL-PCAL_EY_TCAM_PATH1_Y | 64.59614 mm | 65.04131 mm | +0.44517 mm |
| K1:CAL-PCAL_EY_TCAM_PATH2_X | -0.72208 mm | -0.93095 mm | -0.20887 mm |
| K1:CAL-PCAL_EY_TCAM_PATH2_Y | -70.16760 mm | -69.74364 mm | +0.42396 mm |
Update Time: 2025/11/07 11:29:38
| EPICS Key | Before [mm] | After [mm] | Δ (After - Before) [mm] |
|---|---|---|---|
| K1:CAL-PCAL_EY_TCAM_MAIN_X | 9.47443 mm | 5.33197 mm | -4.14245 mm |
| K1:CAL-PCAL_EY_TCAM_MAIN_Y | -3.65031 mm | -2.29115 mm | +1.35917 mm |