Pcal Parameter Update Report

A CAL Tcam session was performed to obtain beam position information necessary for Pcal. The parameters have already been updated, and SDF is expected to be accepted.

Operator: Dan Chen

Update Time: 2025/10/31 08:54:05

EPICS Key Before [mm] After [mm] Δ (After - Before) [mm]
K1:CAL-PCAL_EX_TCAM_PATH1_X 1.25360 mm 0.33702 mm -0.91658 mm
K1:CAL-PCAL_EX_TCAM_PATH1_Y 64.28063 mm 67.43505 mm +3.15442 mm
K1:CAL-PCAL_EX_TCAM_PATH2_X -0.26791 mm -0.10011 mm +0.16780 mm
K1:CAL-PCAL_EX_TCAM_PATH2_Y -64.21604 mm -63.12901 mm +1.08703 mm

Update Time: 2025/10/31 08:54:49

EPICS Key Before [mm] After [mm] Δ (After - Before) [mm]
K1:CAL-PCAL_EY_TCAM_PATH1_X 1.37528 mm 1.07761 mm -0.29767 mm
K1:CAL-PCAL_EY_TCAM_PATH1_Y 64.41668 mm 64.59614 mm +0.17946 mm
K1:CAL-PCAL_EY_TCAM_PATH2_X -0.52695 mm -0.72208 mm -0.19513 mm
K1:CAL-PCAL_EY_TCAM_PATH2_Y -70.02516 mm -70.16760 mm -0.14244 mm

 