takaaki.yokozawa - 13:20 Wednesday 27 November 2024 (31795) Print this report
Health Check MCE
We performed the health check script for MCE.

H1 - H4 higher than reference
L,P Some different shape detected
Y higher than reference
Images attached to this report
Comments to this report:
kenta.tanaka - 20:48 Wednesday 27 November 2024 (31818) Print this report

I updated the reference plots to the recent healthy ones (2024/03/22, after oplev centering, klog28942 ).

The PIT resonance frequecy around 3.5 Hz seems to shift lower, and DC gain slightly increased. The others seem to fine (H2 and H4 measurements seem to be performed at a noisy timing?)

Images attached to this comment
dan.chen - 11:25 Thursday 28 November 2024 (31830) Print this report

With Ohshino-san, Ushiba-san

The latast measurements look healthly.

The difference from the reference data and the reason we think.
At first, we checked the actuator gain (COILOUTF gain) for each coil. The values changed from the reference measurement time.
We think this caused the difference we found.

  • L->Y:
    • Because of the diagonalization after the reference measurement time, 2Hz peak which is the Y resonance went lower.
    • The low frequency region diff should be also caused by this.
  • P->P
    • The overall gain change should be caused by the COILOUTF gain change.
  • P->Y
    • The latest measurement result is much lower than the ref, which means the diagonalization works well.
  • H1->P, H1->P, H4->P
    • These diff are also caused by the COILOUTF gain changes
Images attached to this comment
dan.chen - 11:31 Thursday 28 November 2024 (31836) Print this report

With Oshino-san

We performed the off-load work for MCE.

Procedure

  1. Request `SAFE` to the suspension guardian.
  2. Monitor oplev signal P, Y, Sum
  3. Turn On pico of MCE
  4. Change the pico to make P, Y to be around 0.
  5. Remove offset value during the control
    1. `OPTICALIGN` and `ISCINF` need to be managed.
    2. Remove "offset" of `OPTICALIGN`
    3. Check ASC signal and remove the offset: MEDM -> IMC -> ASC
      1. Check the output matrix of P and Y to see which signal is sent to the suspension.
      2. At this case, DOF_1 is the signal
      3. Open the filter window and click `CLEAR HISTORY`

After this work, we requested LOCK_AQUISITION to check. It works.
Then, we kicked health check script.

shoichi.oshino - 11:43 Thursday 28 November 2024 (31839) Print this report
Before starting offload, OpLev values were below;
TM_OPLEV_TILT_VER: 0.17
TM_OPLEV_TILT_HOR: 0.58

PICO motor counts are below;
PIT: -329 --> -279
YAW: -3220 --> -2090
shoichi.oshino - 14:44 Thursday 28 November 2024 (31846) Print this report
[Tanaka, Oshino]

We updated template files of MCE health check to refer the measurement on 2024/03/22 14:39.
shoichi.oshino - 15:39 Thursday 28 November 2024 (31849) Print this report
I attached the health check results after offloading.
The gain of Y2Y becomes 2 db lager than yesterday's measurement.
This may be due to the effect of adjusting OPLEV_TILT_HOR from 0.6 to around 0.
Images attached to this comment