(Log on 14th)
I investigated the glitches (Fig.1) in the H2 OSEM of the OMMT1 suspension. When the D-sub cable was disconnected from the feedthrough, the glitches disappeared. The LED's voltage drop in forward bias decreased.
| 7/10 | 11/14 | |
| 1-6: PD | 0.704V | 0.710V |
| 2-7: LED | 1.191V | 0.954V |
| 3-8: Coil | 16.8Ω | 16.2Ω |
I found the shield lines in the D-sub cables for H2 and H3 disconnected from the satellite box (arrows in Fig.2). Connecting the shield lines reduced the high-frequency noises (Fig.3), but the glitches did not disappear.