Reports 1-1 of 1 Clear search Modify search
VIS (EY)
ryutaro.takahashi - 17:16 Thursday 26 September 2024 (31134) Print this report
Comment to Test of IP control with accelerometers (30572)

I compared the spectra of each FLDACC (H1, H2, H3) with the spectra before replacing the coil driver from the HPCD to the LPCD in 2023. Though the control status (LVDT only in 2024 and free run in 2023) was different, the noise level in 2024 is much larger than the spectra in 2023. We should check the performance of the present LPCD.

Images attached to this comment