takahiro.yamamoto - 15:35 Friday 20 September 2024 (31099) Print this report
Comment to Helper guardian for lockloss check (31045)
I moved this function from the temporal guardian node (CAL_PROC) to a new node (SYS_LOCKLOSS).

Information of recent two locklosses (latest and previous) are shown on k1mon7. Info. is automatically updated by SYS_LOCKLOSS guardian when a new lockloss is detected. EPICS channels for this info. are still temporal ones. So I need to add new channels with proper name on k1grdconfig.

ndscope plot around latest lockloss time is also automatically launched by SYS_LOCKLOSS on k1mon8. For the lockloss due to known issues (e.g. overflow, earthquake, etc.) related channels are shown on that plot. For unknown issues, ndscope templates in /users/DET/tools/lockloss/share/LSC_LOCK/ will be launched. Template names must be same name as the state name of LSC_LOCK guardian in order to open proper template for each lockloss. (I haven't prepared templates for all states yet.)