Health check of OSTM

I performed OSTM health check.
Figure 1-7 show the TFs from each DoF.

Compared with the TFs in 2023 (klog25967), phases are flipped.
Though phases are flipped now, they seem correct phase, which means phase in previous measurement was flipped from the nominal ones.
So, they seems fine.

Note:

Though current actuator signs are correct locally, actuator signs were flipped from the ones during O4a.
So, OMC ASC signs should be flipped, so it is necessary to treat ASC signs.