The attached figure shows a summary of the current situation IMMT2-PRM-PR2. How do you think about the next step??
- IMMT2's centering is hard to be checked, though.
- Need to also check input GRX spot on the back of PR2 HR target; this spot should overlap on an IR beam reflected at PR2 toward PR3 (not input from IMMT2 to PR2). According to Fig. 3 of 29261, this spot seems also illuminate +Y side of the center line on PR2 HR target, but this should come rather miuns Y side. The target moves together with PR2 traverser, while GRX beam path won't move together with the traverser, as the steering mirror POP-POM is on the suspended table. So this might indicate that PR2 would be dislocated in the minus Y direction now. If we can somehow move PR2 with the traverser in +Y side to some extent (5 mm would be too much? then a few mm...), these mis-centering might be resolved to some extent.