Reports 1-1 of 1 Clear search Modify search
MIF (General)
tomotada.akutsu - 11:21 Saturday 20 April 2024 (29285) Print this report
Comment to Finalization of IFI-IMM-PRM: Day 3 PM; rough check around IFI and IMM (29283)

The attached figure shows a summary of the current situation IMMT2-PRM-PR2. How do you think about the next step??

  • IMMT2's centering is hard to be checked, though.
  • Need to also check input GRX spot on the back of PR2 HR target; this spot should overlap on an IR beam reflected at PR2 toward PR3 (not input from IMMT2 to PR2). According to Fig. 3 of 29261, this spot seems also illuminate +Y side of the center line on PR2 HR target, but this should come rather miuns Y side. The target moves together with PR2 traverser, while GRX beam path won't move together with the traverser, as the steering mirror POP-POM is on the suspended table. So this might indicate that PR2 would be dislocated in the minus Y direction now. If we can somehow move PR2 with the traverser in +Y side to some extent (5 mm would be too much? then a few mm...), these mis-centering might be resolved to some extent.

 

Images attached to this comment
Search Help
×