Reports 1-1 of 1 Clear search Modify search
VIS (EX)
ryutaro.takahashi - 20:45 Wednesday 13 March 2024 (28840) Print this report
Replacement of feedthrough flange

[Ikeda, Washimi, Takahashi]

We replaced the P2 feedthrough flange.

  1. Checked the resistance between all pins in each Dsub connecter on the present flange (leaked previously) without the flip cables.
  2. Removed the present flange.
  3. Tagged a number to all Dsub connectors on the new flange.
  4. Connected the in-vacuum cables to the Dsub connectors.
  5. Checked the resistance between all pins in each Dsub connecter on the new flange without the flip cables.
  6. Checked the resistance between pair pins in each Dsub connecter on the new flange with the flip cables. The gender changers were not used.
  7. Closed the flange with the screws. The torque was 15N-m.
  Old New New (with flip)

1:IP LV1

1-6

2-7

3-8

4-9

 

124Ω

64.5Ω

146Ω

OL

 

120Ω

64.4Ω

146Ω

OL

 

121Ω/21.0mH

64.5Ω/7.7mH

146Ω/39.2mH

OL

2:IP LV2

1-6

2-7

3-8

4-9

 

131Ω

60.4Ω

154Ω

OL

 

124Ω

60.2Ω

154Ω

OL

 

124Ω/22.4mH

60.4Ω/7.6mH

154Ω/40.4mH

OL

3:IP LV3

1-6

2-7

3-8

4-9

 

131Ω

64.4Ω

155Ω

OL

 

131Ω

63.7Ω

157Ω

OL

 

131Ω/24.4mH

65.1Ω/7.8mH

155Ω/40.4mH

OL

4:IP SM1

1-6

2-7

3-8

4-9

 

8.5Ω

8.5Ω

4.5Ω

5.0Ω

 

28.6Ω

25.3Ω

16.2Ω

3.1Ω

 

23.5Ω

22.2Ω

15.0Ω

5.5Ω

5:IP SM2

1-6

2-7

3-8

4-9

 

77.5Ω

8.5Ω

4.9Ω

4.1Ω

 

17.7Ω

8.9Ω

7.5Ω

4.3Ω

 

20.0Ω

9.0Ω

5.0Ω

6.8Ω

6:IP SM3

1-6

2-7

3-8

4-9

 

25.0Ω

9.1Ω

4.0Ω

8.7Ω

 

9.7Ω

11.8Ω

16.1Ω

6.1Ω

 

24.7Ω

22.5Ω

15.8Ω

7.6Ω

7:F0 SMY

1-6

2-7

3-8

4-9

 

25.4Ω

6.3Ω

8.1Ω

14.0Ω

 

6.3Ω

6.2Ω

39.3Ω

11.5Ω

 

7.3Ω

6.4Ω

6.5Ω

8.3Ω

8:F0 SMV

1-6

2-7

3-8

4-9

 

20.1Ω

6.5Ω

OL

10.6Ω

 

10.4Ω

6.6Ω

OL

9.3Ω

 

10.5Ω

6.5Ω

OL

9.3Ω

There were not any cross-connections or ground connections. Some resistance for the stepper motor (SM) became larger. They should be checked again. The 3-8 pin (limit switch) in the F0 SMV was disconnected (OL) because the F0 GAS reached the limit switch.

Images attached to this report
Comments to this report:
tatsuki.washimi - 11:40 Thursday 14 March 2024 (28845) Print this report

Pictures of the notebook

Images attached to this comment
Search Help
×

Warning

×