[Ikeda, Washimi, Takahashi]
We replaced the P2 feedthrough flange.
- Checked the resistance between all pins in each Dsub connecter on the present flange (leaked previously) without the flip cables.
- Removed the present flange.
- Tagged a number to all Dsub connectors on the new flange.
- Connected the in-vacuum cables to the Dsub connectors.
- Checked the resistance between all pins in each Dsub connecter on the new flange without the flip cables.
- Checked the resistance between pair pins in each Dsub connecter on the new flange with the flip cables. The gender changers were not used.
- Closed the flange with the screws. The torque was 15N-m.
| Old | New | New (with flip) | |
| 1:IP LV1 1-6 2-7 3-8 4-9 |
124Ω 64.5Ω 146Ω OL |
120Ω 64.4Ω 146Ω OL |
121Ω/21.0mH 64.5Ω/7.7mH 146Ω/39.2mH OL |
| 2:IP LV2 1-6 2-7 3-8 4-9 |
131Ω 60.4Ω 154Ω OL |
124Ω 60.2Ω 154Ω OL |
124Ω/22.4mH 60.4Ω/7.6mH 154Ω/40.4mH OL |
| 3:IP LV3 1-6 2-7 3-8 4-9 |
131Ω 64.4Ω 155Ω OL |
131Ω 63.7Ω 157Ω OL |
131Ω/24.4mH 65.1Ω/7.8mH 155Ω/40.4mH OL |
| 4:IP SM1 1-6 2-7 3-8 4-9 |
8.5Ω 8.5Ω 4.5Ω 5.0Ω |
28.6Ω 25.3Ω 16.2Ω 3.1Ω |
23.5Ω 22.2Ω 15.0Ω 5.5Ω |
| 5:IP SM2 1-6 2-7 3-8 4-9 |
77.5Ω 8.5Ω 4.9Ω 4.1Ω |
17.7Ω 8.9Ω 7.5Ω 4.3Ω |
20.0Ω 9.0Ω 5.0Ω 6.8Ω |
| 6:IP SM3 1-6 2-7 3-8 4-9 |
25.0Ω 9.1Ω 4.0Ω 8.7Ω |
9.7Ω 11.8Ω 16.1Ω 6.1Ω |
24.7Ω 22.5Ω 15.8Ω 7.6Ω |
| 7:F0 SMY 1-6 2-7 3-8 4-9 |
25.4Ω 6.3Ω 8.1Ω 14.0Ω |
6.3Ω 6.2Ω 39.3Ω 11.5Ω |
7.3Ω 6.4Ω 6.5Ω 8.3Ω |
| 8:F0 SMV 1-6 2-7 3-8 4-9 |
20.1Ω 6.5Ω OL 10.6Ω |
10.4Ω 6.6Ω OL 9.3Ω |
10.5Ω 6.5Ω OL 9.3Ω |
There were not any cross-connections or ground connections. Some resistance for the stepper motor (SM) became larger. They should be checked again. The 3-8 pin (limit switch) in the F0 SMV was disconnected (OL) because the F0 GAS reached the limit switch.