Model file update

Nakano-san, Ushiba-san, Ikeda

Type-A
K1:VIS-{ETMX,ETMY,ITMX,ITMY,}_MN_NBDAMP is added.
 

Non-image files attached to this report
Comments to this report:
satoru.ikeda - 13:32 Thursday 26 October 2023 (27368) Print this report

Ushiba-san, Ikeda

The glitching occurred due to the addition of the filter bank in the last revision(K-Log#27311).
Therefore, SET was removed.
K1:VIS-{ETMX,ETMY,ITMX,ITMY}_PF_SET_{L,P,Y}
K1:VIS-{ETMX,ETMY,ITMX,ITMY}_MN_SET_{L,T,V,R,P,Y}
 

Non-image files attached to this comment
satoru.ikeda - 15:41 Friday 08 December 2023 (27894) Print this report

Ushiba-san, ikeda

Addition to NBDAMP of Type-A model

Update on K-Log#27311

k1vis{etmx,etmy,itmx,itmy}p:
 The following additions were made to NBDAMP for Type-A models.

 Added inputs to DAMP and OLDAMP
 Increased DOF from 5 to 10

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:54 Friday 08 December 2023 (27899) Print this report

Ushiba-san, ikeda

Glitch was caused by a change in K-Log#27894.

Therefore, some filter banks of Type-A were deleted.
Deleted: 
 K1:VIS-{ETMX,ETMY,ITMX,ITMY}_IM_OPTICALIGN
 K1:VIS-{ETMX,ETMY,ITMX,ITMY}_IM_PSD
 K1:VIS-{ETMX,ETMY,ITMX,ITMY}_TM_OPTICALIGN
 

Images attached to this comment
Non-image files attached to this comment
takafumi.ushiba - 16:00 Saturday 09 December 2023 (27906) Print this report

To reduce filter banks further, I deleted the following filter banks:
K1:VIS-{ITMX,ITMY,ETMX,ETMY}_TM_ADD_{L,P,Y}
Figure 1 and 2 show the part of models before and after modification.

During the work, I restarted DAQ at around 16:00.