DetChar (General)nami.uchikata - 11:16 Monday 25 September 2023 (26884)
Print this reportUpdate on the segment list production[Uchikata, Narikawa, Yuzurihara, YamaT] - Latest scripts are available on the github. automation version: https://github.com/gw-detchar/tools/blob/master/Segments/Script/make15minSegment_igwn.py 24 hour version: https://github.com/gw-detchar/tools/blob/master/Segments/Script/make24hourSegment_igwn.py
- O4a segment lists and recent automatically produced segment lists are now available at /home/detchar/Segments/ on m31.
Comments to this report:
hirotaka.yuzurihara - 19:56 Tuesday 26 September 2023 (26917)
Print this report
Related this update, I updated the segment production at Kamioka.
I stopped the operation of previous code (developed by Kozakai-san) at k1det0. The scripts (/users/DET/tools/Segments/Script/run_fine.sh and /users/DET/tools/Segments/Script/make15minSegment.py) are retired.
The runnning server was changed due to the conda enviroment.
The segment of `K1-DET_FRAME_AVAILABLE` will not be generated at Kamioka site well regularly. But, it should run at m31 (or system-B) to monitor the corruption of frame files during the file transfer. I leave it.
The advantage of new script is to add the definition of new segment easily. See the script.
The segment files during O4a (2023-05-24 ~ 2023-06-20) were regenerated at m31 by Uchikata-san and Narikawa-san and were reviewed within the detchar chairs. [review repo] I transfered them to Kamioka (the location is under /users/DET/Segments).
The next step is to transfer the segment files to DQSEGDB.