Similar work with klog25813 and klog25877.
To identified the reesonance of Type-B suspensions, I injected white noise from 10 Hz to 60 Hz at IM stage of Type-B suspensions and measured the spectra of each sensor.
Data are stored at /users/Commissioning/data/VIS/{BS,SR2,SR3}/2023/{0711,0713}/.
I will summarize the results and upload them on JGWdoc soon.