Continued work from klog23588.
I injected white noise excitation from MN stages for all Type-A suspensions.
For translational DoFs, I used 1000 cnts while using 100 cnts for the other DoFs.
Analysis will be done later.
Continued work from klog23588.
I injected white noise excitation from MN stages for all Type-A suspensions.
For translational DoFs, I used 1000 cnts while using 100 cnts for the other DoFs.
Analysis will be done later.
Folowings are the peaks that can be identified.
9.67 Hz: ETMX V
9.69 Hz: ETMY V
9.97 Hz: ITMX V
10.42 Hz: ETMX V
21.01 Hz: ITMY V
21.10 Hz: ETMX V
21.36 Hz: ITMX V
22.20 Hz: ETMY V
22.81 Hz: ITMX R
22.91 Hz: ETMY R
23.14 Hz: ETMX R
38.96 Hz: ITMY V
39.45 Hz: ITMX V
39.55 Hz: ETMY V
39.80 Hz: ETMX V
51.99 Hz: ITMY R
52.53 Hz: ETMY R
53.37 Hz: ITMX R
53.66 Hz: ETMX R
There are also resonances that cannot be seen in DARM sensitivity as follows:
22.95 Hz: ITMY R
I found severl typos in the past post.
I summaried the reults in the documents, so please use it.
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11116