MIF (Noise Budget)
takafumi.ushiba - 22:34 Saturday 01 July 2023 (25813) Print this report
Peak identification in DARM spectrum

Continued work from klog23588.

I injected white noise excitation from MN stages for all Type-A suspensions.
For translational DoFs, I used 1000 cnts while using 100 cnts for the other DoFs.

Analysis will be done later.

Comments to this report:
takafumi.ushiba - 14:19 Monday 03 July 2023 (25830) Print this report

Folowings are the peaks that can be identified.

9.67 Hz: ETMX V
9.69 Hz: ETMY V
9.97 Hz: ITMX V
10.42 Hz: ETMX V
21.01 Hz: ITMY V
21.10 Hz: ETMX V
21.36 Hz: ITMX V
22.20 Hz: ETMY V
22.81 Hz: ITMX R
22.91 Hz: ETMY R
23.14 Hz: ETMX R
38.96 Hz: ITMY V
39.45 Hz: ITMX V
39.55 Hz: ETMY V
39.80 Hz: ETMX V
51.99 Hz: ITMY R
52.53 Hz: ETMY R
53.37 Hz: ITMX R
53.66 Hz: ETMX R

There are also resonances that cannot be seen in DARM sensitivity as follows:
22.95 Hz: ITMY R

takahiro.yamamoto - 19:11 Tuesday 04 July 2023 (25847) Print this report
takafumi.ushiba - 14:08 Monday 10 July 2023 (25924) Print this report