PEM (EY)
tatsuki.washimi - 21:19 Monday 20 March 2023 (24473) Print this report
Vibration from the water pipes

[Suzuki, YokozaWashimi]

Today we measured the vibration from the water pipes in the Y-end.

  1. We located an ACC (TEAC710) near the portable seismometer (see also klog24323) on the under-floor pipe and on the pipes-frame. 
    On the floor, any significant signal from the water was not found. (Blue in Fig.1)
    On the pipes-frame, vibration from the water was observed (Green in Fig.1)
    In both cases, there was no coherence with the seismometer.
  2. We moved the ACC to the floor near the pipes-frame. The vibration from the water disappeared (Pink in Fig.2)
  3. We checked the coherence between the ACC on the pipes-frame and the oplevs.  There was no coherence. (Fig. 3) 