satoru.ikeda - 20:16 Friday 20 May 2022 (20819) Print this report
Comment to Routine confirmation of DGS maintenance day (17831)

DGS Regular maintenance day (5/20) 

Stepper motor
 [Check the motor.]
  Check if power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  PR2(IM),SR3(BF)
   => It was hung and recovered.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Checked only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,STM)
  PRM(IM,BF),PR2(BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS, (new check item)POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used.

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] ・Is the temperature acquisition working properly?
  No problem

Precision air conditioning
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation) ・Is there a ping response?
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

Images attached to this comment