[Ikeda, Oshino-san, (remote)Yamamoto-san]
This is last Friday's work.
This is a continuation of K-Log#20547.
Work contents
1. C1 network SW was replaced with another SW (M100-26G V2H2).
 Then, LAN connection was restored to the state where the error (0x4000) occurred.
Check result :
There was no improvement in DAQ error (0x4000).
2. Connected all RTPCs (C1, C2, C3) directly to the SW of NETGEAR to which k1dc0 is connected.
Confirmation Result :
There was no improvement of DAQ error (0x4000).
Error Description:
k1iopomc0 is 0x4000
k1visostm is 0x4000
k1ioppr0 is 0x4000
k1visommt2 is 0x4000
k1vispr3p is 0x4000
k1omc is 0x4000
k1pemiy0 is 0x4000
k1vispr3t is 0x4000
k1vistmsx is 0x4000
k1pemex0 is 0x4000
k1visommt1 is 0x4000
k1iopex0 is 0x4000
k1vispr2t is 0x4000
k1iopmcf0 is 0x4000
k1calex is 0x4000
k1iopbs is 0x4000
k1calext is 0x4000
k1visbsp is 0x4000
k1aosiyanab is 0x4000
k1aosiycwab is 0x4000
k1tmsx is 0x4000
k1visbst is 0x4000
k1vispr2p is 0x4000
k1alspll is 0x4000
3. The CPU settings were checked in the BIOS settings of k1dc0.
Check Result :
There was no setting that lowered the CPU clock.
4.Finally, I restored all connections to K-Log#20498.
> Finally, k1ioo, k1ioo1, k1imc in the C1 rack and k1bs in the C2 rack were connected to the DAQ switch in the B1 rack directly.