VIS (SRM)
fabian.arellano - 17:18 Thursday 21 October 2021 (18649) Print this report
Comment to Lowering the pre-isolator. (17033)

With Hirata-san.

Summary: the mirror (RM) is 2.8 mm below the expected height of the beam when the GAS filters are at the setpoints.

See pictures in SRM Remedying Work album.

  • Temperature T_PT100 = 22.9 °C , T_ondotori = 22.9 °C (O3GK T_ondotori = 22.9 °).
  • We set the GAS filters to zero:
    • F0: we used the FR but it reached its lower limit, then we used -7,500 counts of coil-magnet actuator.
    • F1: we used -13,650 counts of coil-magnet actuation.
    • BF: we used -4,450 counts of coil-magnet actuation.
  • Then we measured the height of the RM with respect to Tomaru-san's making of the expected beam height pasted either yesterday or today.
  • The RM is 2.8 mm below the reference.
Images attached to this comment