Routine confirmation of DGS maintenance day(Aug.27)
Performed routine check of DGS maintenance day.
No problems other than known problems.
Stepper motor
[Checked]
Checked if the power supply can be controlled by BIO.
Checked if Script can be started.
Check that the limit switch installed is green.
[Check result]
ETMY:
Power control: No problem
Limit SW: currently all NG, but will be adjusted in the future (known)
ITMY:
Power control: No problem
Limit SW: F0YAW is NG (known)
Other than above: No problem
Release Sensor
[Confirmation]
Confirmed that Release Sensor is 0. 1: Seated
[Check result]
ETMY, ITMX, ITMY : No problem
ETMX_F1_1 : Abnormal, no other problems (known)