We set these parameters to the low latency and restarted it on 17:22 JST. The filter file name is 2020-04-21_v2_FIRfilters.npz.
After updating the parameters of online, the low latency could output the correctly calibrated h(t).
A rough consistency check of the actuation strengths with the FSM + MICH measurements, using a method developed by W. Ogaki (a previoius such measurement can be found in klog 11754).
Below we provide our preliminary results.
From FSM,
Then, with MICH locked, the following quantities were aquired:
From this we can estimate A_ETMX and A_ETMY actuator strengths:
The MICH result for A_EXTM is within 17% of the DARM result. And for A_EYTM, within 6%.
We have not analyzed the uncertainties associated with MICH results yet.
Each of the estimated values are weighted averages taken from TF measurements (weights were set using coherences associated with the measurements).