Reports 1-1 of 1 Clear search Modify search
VIS (General)
satoru.ikeda - 13:56 Friday 02 July 2021 (17369) Print this report
Added EPICS channel for VIS temperature adjustment

An EPICS channel for VIS temperature adjustment has been added to the SdfManager model.

Target temperature of the ribbon heater outside the chamber and the measured temperature of the thermocouple
K1:VIS-{optic}_HEATER_PV: Current temperature (Centigrade)
K1:VIS-{optic}_HEATER_SV:Target temperature of the heater (Centigrade)
optic: PRM,PR2,PR3,BS,SRM,SR2,SR3,ITMX,ITMY,ETMX,ETMY

Measured temperature of the resistance thermometer (PT100) inside the chamber
K1:VIS-{optic}_CHAMBER_PV:Current temperature (Centigrade)
optic: PRM,PR2,PR3,BS,SRM,SR2,SR3

Currently, no devices are connected yet.
 

Non-image files attached to this report
Comments to this report:
satoru.ikeda - 10:57 Friday 16 July 2021 (17553) Print this report

Changed the name of the EPICS channel for temperature control.

Target temperature of the ribbon heater outside the chamber and the measured temperature of the thermocouple
K1:VIS-{optic}_HEATER_PV => K1:VIS-{optic}_TEMPERATURE_HEATER_PV
K1:VIS-{optic}_HEATER_SV => K1:VIS-{optic}_TEMPERATURE_HEATER_SV
optic: PRM,PR2,PR3,BS,SRM,SR2,SR3,ITMX,ITMY,ETMX,ETMY

Measured temperature of the resistance thermometer (PT100) inside the chamber
K1:VIS-{optic}_CHAMBER_PV => K1:VIS-{optic}_TEMPERATURE_CHAMBER_PV
optic: PRM,PR2,PR3,BS,SRM,SR2,SR3

Currently, no devices are connected yet.
 

Non-image files attached to this comment
satoru.ikeda - 11:43 Friday 06 August 2021 (17830) Print this report

Added channel for data acquisition interval for VIS temperature control devices.

K1:VIS-TEMPERATURE_UPDATE_INTERVAL channel is added.
The unit is planned to be operated in msec.

Non-image files attached to this comment
Search Help
×