温度調整用のEPICSチャンネル名を変更しました。 チャンバーの外のリボンヒーターの目標温度と熱電対の測定温度 K1:VIS-{optic}_HEATER_PV => K1:VIS-{optic}_TEMPERATURE_HEATER_PV K1:VIS-{optic}_HEATER_SV => K1:VIS-{optic}_TEMPERATURE_HEATER_SV optic: PRM,PR2,PR3,BS,SRM,SR2,SR3,ITMX,ITMY,ETMX,ETMY チャンバーの内の測温抵抗体(PT100)の測定温度 K1:VIS-{optic}_CHAMBER_PV => K1:VIS-{optic}_TEMPERATURE_CHAMBER_PV optic: PRM,PR2,PR3,BS,SRM,SR2,SR3 現在は、まだ機器が接続されていない。 --- Changed the name of the EPICS channel for temperature control. Target temperature of the ribbon heater outside the chamber and the measured temperature of the thermocouple K1:VIS-{optic}_HEATER_PV => K1:VIS-{optic}_TEMPERATURE_HEATER_PV K1:VIS-{optic}_HEATER_SV => K1:VIS-{optic}_TEMPERATURE_HEATER_SV optic: PRM,PR2,PR3,BS,SRM,SR2,SR3,ITMX,ITMY,ETMX,ETMY Measured temperature of the resistance thermometer (PT100) inside the chamber K1:VIS-{optic}_CHAMBER_PV => K1:VIS-{optic}_TEMPERATURE_CHAMBER_PV optic: PRM,PR2,PR3,BS,SRM,SR2,SR3 Currently, no devices are connected yet.