shoichi.oshino - 14:39 Friday 24 July 2026 (37256) Print this report
Preparation for k1sdfmanage model update
[Oshino, Ikeda]

We modified the k1sdfmanage RT model to add EPICS channels for the Ondotori sensors.
Since these channels are linked via the shared MOZUMILIBS library, we edited the library block directly, adding 3 new EPICS blocks.
Before editing, we created a backup copy of the library file.
After saving the library, we logged into k1test0 and successfully built the model with make k1sdfmanage with no errors.
Note: make install has not yet been done.
Images attached to this report
Comments to this report:
shoichi.oshino - 17:08 Monday 27 July 2026 (37273) Print this report
We performed installation work of the k1sdfmanage on k1test0. After installation, the DAQ process was also restarted.