Reports 1-1 of 1 Clear search Modify search
AOS (Beam Reducing Telescopes)
yoichi.aso - 17:19 Thursday 05 March 2026 (36501) Print this report
Signal generator for the TMSX LVDT is dead

During the recovery work from the blackout, I noticed that the signal generator used for the LO of the LVDTs of the TMSX-VIS was dead. 

When I turned on the generator, it showed "SYSTEM TEST FAILED 001" immediately.

The generator was turned off and the AC cable was removed before the blackout. Still, it is dead now. Probably it was near the end of its lifetime. R.I.P.

As the TMSX-VIS is not actively controlled at this moment, this will not cause any immediate problem.
Yet, we should replace the signal source asap.

Images attached to this report
Comments to this report:
ryutaro.takahashi - 13:34 Tuesday 17 March 2026 (36599) Print this report

[Washimi, Takahashi]

We replaced the broken signal generator (SG) NF1956 with the embedded SG card for the LVDT driver (S1807787) in TMSX. We opened the driver chassis and inserted the SG card. The output of the SG card was connected to "REF IN" port on the front panel. The signal was set to 10kHz in frequency and 7Vp-p in amplitude.