DetChar (General)takahiro.yamamoto - 15:46 Monday 02 March 2026 (36476)
Print this reportUpdates of makeCache scriptAs a part of migration work to the new script server prepared in klog#36430, I updated makeCache script and moved it from k1script1 to k1script0.
----- Details of update makeCache script had a duplication issue such as klog#34595 and we sometimes needed to fix cache files by manually. For future observing runs, I rewrote the makeCache script to remove this issue. And also, scatterred scripts for each frame type such as full, science, second, etc. were merged to one new script. Old makeCache.sh which can provide only full frames cache was renamed as makeCache_FullFrame.sh and the new script was added as makeCache.sh.
These changes was made in the origin/ir1-upgrade branch and haven't been merged to the origin/master branch. And also, it was deployed at Kamioka by switching a branch of /users/DET/tools. Now the old scripts on k1script1 was stopped and the new script is launched on k1script0. I haven't prepared a condor submission file, so the old scripts in the origin/master branch are still being used at Kashiwa. After preparing the condor submission file, we can use it at Kashiwa and merge origin/ir1-upgrade branch to the origin/master branch.
By the way, I added a 'O4c' tag to a current HEAD of the origin/master branch as a snapshot of softwares used during O4c.
A change in the mountpoint of DET servers Some DET servers still mounted the hyades-1 disk and used the hyades-0 disk as a primary one. But hyades-1 has ready retired and is currently on standby as a backup server. So I chagend mountpoint from the hyades-1 disk to the hyades-2 disk and the hyades-2 disk is set as the primary disk because it can store files during longer term than the hyades-0 disk.
Comments to this report:
takahiro.yamamoto - 20:02 Wednesday 04 March 2026 (36490)
Print this reportThe new makeCache script is now running as a debug-mode on detchar@Kashiwa cluster. After confirming that an output produced by the old and the new script is identical, the old script will be stop and migrated to the new script.
----- The launched script is located as ~takahiro.yamamoto/.local/src/git/detchar/tools/Cache/Script/makeCache.sh which is one in ir1-upgrade branch. Submission to HTCondor was done via condor-makeCache.sh in same directory, which creates a submission file automatically and can show or submit that submission file. Cache files by this script are being served in /home/detchar/Desktop/cache/ as a behavior of the debug-mode.