PEM (Center)takaaki.yokozawa - 8:12 Friday 20 February 2026 (36400)
Print this reportPEM injection test 260220I performed the PEM injection test, especially the durability test(耐久試験) for the vibration o the OMC floor. During this measurement, I turned off the BPC control loops.
5:20 - 5:30 silent run
05:32:00 - 05:37:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white wide frequency, 2,000 cnt
05:37:00 - 05:42:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white wide frequency, 3,000 cnt
05:42:00 - 05:47:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white wide frequency, 4,000 cnt
05:47:00 - 05:52:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white wide frequency, 5,000 cnt
05:54:00 - 06:00:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 50 - 200, 3,000 cnt
06:00:00 - 06:05:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 50 - 200, 6,000 cnt
06:05:00 - 06:10:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 50 - 200, 9,000 cnt
06:10:00 - 06:16:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 200 - 300, 9,000 cnt
06:16:00 - 06:21:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 300 - 400, 9,000 cnt
06:21:00 - 06:26:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 400 - 500, 9,000 cnt
06:26:00 - 06:31:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 500 - 600, 9,000 cnt
06:31:00 - 06:36:00 EXC channel : K1:PEM-EXCITATION_SR3_RACK_7_EXC REF : K1:PEM-ACC_OMC_CHAMBER_OMCLEG_Z_OUT_DQ Mini shaker 8, white 600 - 700, 9,000 cnt
Short silent run BPC on during silent run and off after that
Fig.1. showed the mini shaker result 50 - 700 Hz excitation Fig.2. showed the large shaker result 1 - 200 Hz excitation
Images attached to this report
Comments to this report:
takaaki.yokozawa - 10:48 Friday 20 February 2026 (36407)
Print this reportI performd the Washimi-san's transfer function of the klog36385.
This result was the maximum vibration for the band-limited white noise injection. (And I didn't take into account the sensor response function)
But in case of the unit of the m/s^2, 10^-4 m/s^s (below 250 Hz) 10^-3 m/s^2 (250 - 400 Hz) when we turned off the BPC control if we would like to check above 400 Hz, we need the re-measurement of the transfer function.
Images attached to this comment
takaaki.yokozawa - 9:27 Saturday 28 February 2026 (36466)
Print this reportSorry I missed the method of the calibration using the diaggui. Transfer function of the OMC stack (V->V) can be found in JGWDoc17204
Fig.1. showed the unit of the (m/s^2) with the transfer function of the OMC stack (V->V) Fig.2. showed the unit of the (m/s), multiplying 1/f with the transfer function of the OMC stack (V->V) Fig.3. showed the unit of the (m), multiplying 1/f^2 with the transfer function of the OMC stack (V->V)