PEM (EY)
takaaki.yokozawa - 8:23 Thursday 29 January 2026 (36243) Print this report
PEM injection test 260129
I performed the PEM injection test

- 5/14 silent run

Shake injection to TMSY table EXC1
01/29 05:14:00 - 05:19:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ
Info : White injection 380-520 Hz 1000 count

Shake injection to TMSY table EXC1
01/29 05:19:00 - 05:24:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ
Info : White injection 280-420 Hz 2000 count

Shake injection to TMSY table EXC1
01/29 05:24:00 - 05:29:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ
Info : White injection 180-320 Hz 2000 count

Shake injection to TMSY table EXC1
01/29 05:29:00 - 05:34:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ
Info : White injection 80-320 Hz 2000 count

Shake injection to TMSY table EXC1
01/29 05:34:00 - 05:39:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ
Info : White injection 45-105 Hz 3000 count

Locked loss happened

Shake injection to TMSY table EXC1
01/29 06:30:00 - 06:35:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ
Info : White injection 1-55 Hz 3000 count

Shake injection to TMSY table EXC1
01/29 06:40:00 - 06:50:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ
Info : Sweep 600 -1 Hz 100 cnt 600s


Shake injection to TMSY table EXC2
01/29 07:27:00 - 07:33:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ
Info : White injection 380-520 Hz 1000 count

Shake injection to TMSY table EXC2
01/29 07:33:00 - 07:38:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ
Info : White injection 280-420 Hz 2000 count

Shake injection to TMSY table EXC2
01/29 07:38:00 - 07:43:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ
Info : White injection 180-320 Hz 2000 count

Shake injection to TMSY table EXC2
01/29 07:43:00 - 07:48:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ
Info : White injection 80-320 Hz 2000 count

Shake injection to TMSY table EXC2
01/29 07:48:00 - 07:53:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ
Info : White injection 45-105 Hz 3000 count

Shake injection to TMSY table EXC2
01/29 07:53:00 - 07:58:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ
Info : White injection 1-55 Hz 3000 count

Shake injection to TMSY table EXC2
01/29 08:00:00 - 08:30:00 (JST)
EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC
REF : K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ
Info : Sweep 600 -1 Hz 100 cnt 600s
Comments to this report:
tatsuki.washimi - 12:03 Thursday 29 January 2026 (36244) Print this report

I analized the white noise shaker injection at positition 1 (EXC : K1:PEM-EXCITATION_EY0_RACK_1_EXC, K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB25_OUT_DQ).

There were no significant excess in the DARM.

I assumed the coupling from ACC -> QPDs are liner and applied the Coupling Function model.

Images attached to this comment
tatsuki.washimi - 13:26 Thursday 29 January 2026 (36245) Print this report

I also  analized the white noise shaker injection at positition 2 (EXC : K1:PEM-EXCITATION_EY0_RACK_2_EXC, K1:PEM-PORTABLE_EYC_RACK_EY0_ADC0_DSUB26_OUT_DQ).

Some  very small excess in the DARM were found at 115, 250, 300, 660,  780, 855 Hz.

Images attached to this comment