Reports 1-1 of 1 Clear search Modify search
CAL (General)
dan.chen - 7:09 Saturday 10 January 2026 (36096) Print this report
O4a Calibrated Reconstruction Data Verification

Background

We are working toward the open release of the O4a calibrated reconstruction data.
In parallel with the production of the main dataset, I am also developing verification scripts for the product data.

Guideline

The verification scripts are intended to check the following points:

  • Check 1: Verify that there are no missing data in the product data and that the data structure is correct.
  • Check 2: Compare appropriate state vectors between the production data and the raw data, and verify that they are consistent with each other.
  • Check 3: (Possibly applicable only to the O4a case) Construct the transfer function between the production h(t) and the online h(t), and verify that it behaves as expected.

Current Status

I have completed the scripts for Check 1 and Check 2. For both checks, I have also finished tests using mock data, and the results were as expected.

Detailed Working Logs:

Next Steps

  • Apply the verification scripts (check 1 and 2) to the actual O4a data.
  • Develop the script for check 3
Comments to this report:
dan.chen - 10:37 Monday 09 March 2026 (36526) Print this report

The Check 3 script has been developed and tested.
The comparison between the LL spectrum and the RAW-based reconstructed spectrum shows generally good agreement.

Detailed Working Logs:

 

Search Help
×

Warning

×