Reports 1-1 of 1 Clear search Modify search
VIS (EX)
takaaki.yokozawa - 8:32 Thursday 08 January 2026 (36065) Print this report
Suspension commissioning 2026 ETMX
I started the suspension commissioning ETMX
First, I measured the spectrum with excitation.
Fig.1 - Fig.6. showed the results compared with the Aug 2024
Images attached to this report
Comments to this report:
dan.chen - 8:01 Tuesday 13 January 2026 (36109) Print this report

We adjuseted NBDAMP filters (L1,2,3, and 5)

  • L1: changed the filter from FM3(pink) to FM1(red)
  • L2: changed the filter from FM3(brown) to FM1(red)
  • L3: checked FM3(original one) and FM1(300K one). As FM3(brown) looks better than FM1(red), we keep using FM3.
  • (L4: not be closed at LOCK_AQUISITION)
  • L5: Measured TF had too large gain peaking. So we comment out the line which closes this loop in the guardian code.

After this work, we checked the ETMX suspension can reach the LOCK_AQUISISION state and back to ISOLATED state. (The L5 loop was not closed as we expected.)
The current temperature of ETMX is 270K.

 

Images attached to this comment
dan.chen - 10:49 Tuesday 13 January 2026 (36118) Print this report

We adjusted T1-T3 NBDAMP filters.

  • T1: Changed from FM3(pink) to FM1(cyan), and adjusted FM1(red)
  • T2: Changed from FM3(brown) to FM1(red)
  • T3: Copied FM3(cyan) to FM5 and modified FM5(5.336, 271K) for the adjustment.

 

Images attached to this comment
takaaki.yokozawa - 9:03 Wednesday 14 January 2026 (36127) Print this report
I performed the following NB and wide filter tuning

(Wide)
MN DAMP L
MN DAMP T

(NB)
P1
Y1, Y2, Y3 and Y4 (with spectrum of the IM Y photo sensor)

Images attached to this comment
takaaki.yokozawa - 7:56 Thursday 15 January 2026 (36137) Print this report
I performed the re-tuning for the ETMX suspensions

NBDAMP
L1, L2, L3
T1, T2, T3

MNDAMP
L, T

MNOLDAMP
R, P, Y

Even after tuning the following filters, the ETMX suspension started oscillating around 1.67 Hz.
I changed the MNOLDAMP R, P notch fireqencies (1.685 -> 1.67) and turned off the ACALIGN matrix K1:VIS-ETMX_MN_ACTALIGN_6_5 (P->Y) from 0.017 to 0 (temporary)
The oscillation can be stopped(at least 1 hour).
So, next step would be ALS DARM lock!
Images attached to this comment
Search Help
×