Reports 1-1 of 1 Clear search Modify search
MIF (General)
takaaki.yokozawa - 8:10 Thursday 22 May 2025 (33860) Print this report
Finesse measurement Yarm 250522
DATE : 2025/05/21 22:42 UTC                                                                                                                                                 
ARM : Y
TEMP ITM : 37.3
TEMP ETM : 42.5
NUM : 10
IFO REFL HWP : 152.0
PSL HWP : 173.0
IMC POWER : 6.3
VALUE : 1290.2
ERROR : 8.2
Measured data is stored to /users/Commissioning/data/Finesse/Yarm/20250521-224243
 
https://gwdet.icrr.u-tokyo.ac.jp/~controls/trendMon/finesse.html
Images attached to this report
Comments to this report:
hirotaka.yuzurihara - 15:36 Thursday 22 May 2025 (33870) Print this report

DATE : 2025/05/22 06:00 UTC                                                       
ARM : Y
TEMP ITM : 37.5
TEMP ETM : 42.4
NUM : 10
IFO REFL HWP : 152.0
PSL HWP : 173.0
IMC POWER : 6.6
VALUE : 1293.7
ERROR : 8.6

Measured data is stored to /users/Commissioning/data/Finesse/Yarm/20250522-0600374

The result is almost consistent with one of this moring.

Images attached to this comment
Search Help
×