MIF (General)Chia-Jui Chou - 16:20 Monday 20 January 2025 (32396)
Print this reportNoise Subtraction using DeepClean on O4a Beam Jitter NoiseBeam jitter noise around 120 Hz is related to K1:IMC-IMMT1_TRANS_QPDA2_DC_PIT_OUT_DQ. The coherence between K1:CAL-CS_PROC_DARM_STRAIN_DBL_DQ and K1:IMC-IMMT1_TRANS_QPDA2_DC_PIT_OUT_DQ are confirmed (Fig. 1). Then DeepClean model is trained by the witness channel above from 1368982000 s to 1368983024 s (1024-second of science mode data from O4a). Then I used the witness channel to clean the noise in the band [110Hz, 135Hz] of K1 strain data from 1368983024 s to 1368987120 s (4096-second of science mode data from O4a). The noise can be recognized and reduced and the inspiral range is improved by 0.001248% (Fig. 2).
Images attached to this report
Comments to this report:
Chia-Jui Chou - 12:00 Tuesday 21 January 2025 (32407)
Print this reportThe coherence between K1:CAL-CS_PROC_DARM_STRAIN_DBL_DQ and K1:IMC-IMMT1_TRANS_QPDA2_DC_PIT_OUT_DQ is estimated. Fig. 1 shows the coherence between the raw strain and the IMMT1 channel before and after cleaning. Fig. 2 shows the difference of the coherence between the cleaned strain and the IMMT1 channel before and after cleaning.
The subtracted noise is bandpass filtered by [110Hz, 135Hz].