Reports 1-1 of 1 Clear search Modify search
PEM (Center)
tatsuki.washimi - 13:05 Friday 27 December 2024 (32171) Print this report
Large Coil for Magnetic Injection @ CS

We located the Magnetic Injection Large Coil (klog30893) to the nominal position (klog31506).

We also tried to make magnetic fields using a function generator (directly, without an amplifier) with 4.1Hz, 20.1Hz, 40.1Hz, and 80.1Hz sine waves.
The permanent magnetometer observed the injected lines.

Images attached to this report
Comments to this report:
tatsuki.washimi - 18:43 Tuesday 21 January 2025 (32420) Print this report

Today I measured the Resistance and Inductance of the Large Coil.

  Design klog30893 today
Resistance @ DC 8.3 Ω 8.4 Ω 8.5 Ω
Inductance @ 1kHz 112 mH 111 mH 116 mH
Images attached to this comment
Search Help
×