CRY (Cryo-payload EY)
takafumi.ushiba - 16:18 Thursday 25 January 2024 (28420) Print this report
Apply current to the IM heater on EY payload

I applied 0.2A to the IM heater on ETMY (fig1).

Images attached to this report
Comments to this report:
takafumi.ushiba - 17:44 Friday 09 February 2024 (28565) Print this report

I turned off ETMY IM heater.

takafumi.ushiba - 10:32 Tuesday 11 March 2025 (32953) Print this report

I applied current of 0.074 A to ETMY IM heater (fig1).

Images attached to this comment
shinji.miyoki - 8:29 Monday 17 March 2025 (33001) Print this report

ETMY IM temp kept increasing, in contrast with  ITMX IM temp as Fig.1. It is strange.

Fig.2 shows the volatile cooling performance of the cryocooler for REF4 for ETMY as you know. So it is better to stop this cryocooler ore try stop and restart.

Images attached to this comment
takafumi.ushiba - 14:11 Monday 17 March 2025 (33007) Print this report

I reduced the heater power as shown in fig1.

Images attached to this comment
shinji.miyoki - 7:29 Tuesday 18 March 2025 (33017) Print this report

EX Im temp is decreasing with fluctuation again. EY IM temp is also decreasing slowly (Fig.1).

Fig.2 seems to show the decrease in the heat reduction rate of EX_4K_REF2/4_4K_Head when the heater was on. while no relation was found btw EY IM temp and EY_4K_REF2/4_4K_Head.

Fig.3 shows the close-up of the recent 1-day data. In EX, the IM temp and REF2/4 4K head temps have a clear correlation. While, in EY, no correlation between the IM temp and REF4 4K head temp. Very strange?

Images attached to this comment
shinji.miyoki - 15:29 Wednesday 19 March 2025 (33037) Print this report

The temps' changes of EXY IMs seem to become smaller.

Images attached to this comment
shinji.miyoki - 7:00 Friday 28 March 2025 (33143) Print this report

I increased the heater power as shown in fig1.

Images attached to this comment
shinji.miyoki - 21:28 Friday 28 March 2025 (33155) Print this report

EXY Im temps. EX Im temp is increasing. EY Im temp is near constant.

Images attached to this comment
shinji.miyoki - 8:07 Monday 31 March 2025 (33165) Print this report

The current was increased by changing the voltage to 8.900V.

Images attached to this comment
shinji.miyoki - 9:58 Thursday 03 April 2025 (33205) Print this report

The current was increased by changing the voltage to 9.197V.

Images attached to this comment
shinji.miyoki - 13:50 Friday 04 April 2025 (33246) Print this report

The current was decreased by changing the voltage to 9.500V.

Images attached to this comment
takafumi.ushiba - 10:09 Wednesday 07 May 2025 (33690) Print this report

I reduced the heater power.

Images attached to this comment
shinji.miyoki - 21:54 Thursday 08 May 2025 (33716) Print this report

I reduced the voltage from 4 to 3 to accelerate the IM temp reduction.

shinji.miyoki - 21:19 Friday 09 May 2025 (33717) Print this report

I reduced the voltage from 2.5 to 1.0 to accelerate the IM temp reduction.

shinji.miyoki - 7:24 Saturday 10 May 2025 (33729) Print this report

I reduced the voltage from 1.0 to zero to accelerate the IM temp reduction. However, no remarkable temp reduction happened during my recent actions. It is strange. My setting is right?

takafumi.ushiba - 11:24 Wednesday 27 August 2025 (34927) Print this report

I increased the current for IM heater on ETMY to warm up ETMY.

Images attached to this comment
takafumi.ushiba - 14:08 Wednesday 27 August 2025 (34930) Print this report

I increased the current for ETMY IM heater.

Images attached to this comment
takafumi.ushiba - 12:17 Thursday 28 August 2025 (34940) Print this report

I increased the current for ETMY IM heater.

Images attached to this comment
takafumi.ushiba - 9:16 Friday 29 August 2025 (34953) Print this report

I reduced the current for ETMY IM heater because ETMY temp is now more than 100K.

Images attached to this comment
takafumi.ushiba - 11:01 Tuesday 02 September 2025 (34989) Print this report

I increased ETMY IM heater for further warming up (fig1).

Images attached to this comment
shinji.miyoki - 8:04 Thursday 04 September 2025 (35004) Print this report

The temperature of IM of EY reached the critical temperature! It is much faster than we expected (Fig.1). Fig.2 shows the temperatures in the EY cryostat. Other temperature seemed to be lower than the critical temperature. Rather, the temperature of 40K heads of all cryocoolers started to reduce after the heater current increased.

However no change in the Qmass data at present. Of course, the temperature of the test mass should be cooler than IM's at present. According th the past experiences in the radiation duct shield, slight enhancement of water started from around 145K~150K. The outgas from IM was just being absorbed on other cooled area in the ceyostat and did not reach the Qmas? 

Images attached to this comment
shinji.miyoki - 8:39 Friday 05 September 2025 (35011) Print this report

3 days have passed after the warming up. Both EX/Y IMs temperatures were over the critical temperature. However, it seemes to be difficult or to take long time to reach 180K or more without more current for the IM heaters.

Images attached to this comment
takafumi.ushiba - 9:36 Thursday 11 September 2025 (35066) Print this report

I turned off IM heater for cooling ETMY again.

shinji.miyoki - 20:30 Monday 15 September 2025 (35079) Print this report

IM Temperatures are still decreasing. However, IY and EX temps decreased rapidly. So it is better to set some amount of current for IY/EX heater within one or two days.

Images attached to this comment