LAS (bKAGRA laser)Taishi Sako - 17:57 Tuesday 24 January 2023 (23685)
Print this reportConverter installing and PZT resonant checking.1, I installed modified Dsub-BNC converter into ISS lack. the converter has twice gain than normal one. As a result, the PZT adjustment range has been expanded. 2, I have input white noise to check the resonance of the PZT. I want to increase the resonance frequency and reduce the peak because PZT resonance can interfere with control. I was able to increase the 395Hz resonance a little by tightening the screws tighter. I was also able to lower the peak by inserting rubber under the mirror mount, but it became unstable, so I removed it immediately.
Images attached to this report
Comments to this report:
Taishi Sako - 18:08 Tuesday 24 January 2023 (23687)
Print this reportremoved normal converter(S2214289) was return to mozumi office. modefied converter number is S2214278.