Reports 1-1 of 1 Clear search Modify search
VAC (Valves & Pumps)
nobuhiro.kimura - 14:52 Friday 01 April 2022 (20329) Print this report
Opened gate valve between IXV and #29 vacuum pomp set
Who: Kimura (ICRR) and Yasui (ICRR)
Task:
Opened gate valve between IXV and #29 vacuum pomp set at 14:39 on 01/Apr./2022.
The pressure changes before and after opening the valves between IXV and #29 vacuum pomp set are shown below.
Before:
The pomp side:1.8 x 10^-6 Pa

After:
The pomp side:7.2 x 10^-6 Pa

Now, IXV is evacuated by the #29 vacuum pomp set.
Please confirm attached photos.
Images attached to this report
Comments to this report:
shinji.miyoki - 11:16 Sunday 03 April 2022 (20346) Print this report

Because I found the temp enhancement at IXV by 0.4C, I reduced the heating power of the delongi heater from level 5 to 3 around 11am on April 3rd.