[Ushiba, Lucia]
We used the TFs and the Yamada-kun script to make the typeA control noise projection when the best sensitivity curve has been measured:
-time: 2020/03/09 13:57 UTC
- BNS 594 Kpc
The attached plots show the control noise projection for each TypeA suspension and the total contributions.
Looking at these plots seems that @ 100 Hz, the ITMX MNL_PS control noise is limiting the sensitivity.
To reduce this re-injection of noise,we are planning to add an addition rolloff filter in the PS_MN_L control for all typeA suspensions.
Note:
The data, the script (plot.py) ans TFs are saved in:
/kagra/Dropbox/Subsystems/VIS/AutoMeasurement/TypeA/Noisebudget_py